EN50082-1 @ SMPS Power Supplies

EN50082-1 Electromagnetic compatibility - Generic immunity standard  
    Part 1: Residential, commercial and light industry  
             
             
  EN/HD Publication Suggested Suggested    
      levels criteria    
  - IEC 50(161)        
  EN 61000-4-2 IEC 1000-4-2 2 & 3 B    
  EN 61000-4-3 IEC 1000-4-3 2 A    
  EN 61000-4-4 IEC 1000-4-4 2 B    
  EN 61000-4-5 IEC 1000-4-5 3 B    
  EN 61000-4-6 IEC 1000-4-6   A    
  EN 61000-4-8 IEC 1000-4-8   A    
  EN 61000-4-11 IEC 1000-4-11      
  EN 55022 CISPR 22        
  ENV 50204/1995 -   A    
             
             
Definitions:          
  Port: Particular interface of the specified apparatus with the external  
    electromagnetic environment.    
             
  Enclosure port: The physical boundary of the apparatus which electromagnetic fields may
    radiate through or impinge on.    
             
  Cable port: A point at which a conductor or cable is connected to the apparatus.
    Example are signal,control and power ports.  
             
  Public mains Electricity lines to which all categories of consumers have access and
  network: which are operated by supply or distribution undertaking for the purpose
    of supplying electrical energy.    
             
  Functional A point on the apparatus which is connected to earth for the purposes
  earth port: other than electrical safety.      
             
             
 
Performance criteria:          
  A: The apparatus shall continue to operate as intended. No degradation of
    performance or loss of function is allowed below a performance level
    specified by the manufacturer, when the apparatus is used as intended.
    The performance level may be replaced by a permissible loss of  
    performance. If the minimum performance level or the permissible  
    performance loss is not specified by the manufacturer then either of
    these may be derived from the product description and documentation
    and what the user may reasonable expect from the apparatus if used as
    intended.        
             
  B: The apparatus shall continue to operate as intended after the test. No
    degradation of performance or loss of function is allowed below a  
    performance level specified by the manufacturer, when the apparatus is
    used as intended. The performance level may be replaced by a  
    permissible loss of performance. During the test, degradation of  
    performance is however allowed. No change of actual operating state or
    stored data is allowed. If the minimum performance level of the  
    permissible performance loss is not specified by the manufacturer then
    either of these may be derived from the product description and  
    documentation and what the user may reasonable expect from the
    apparatus if used as intended.    
             
  C: Temporary loss of function is allowed, provided the function is self  
    recoverable or can be restored by the operation of controls.  
             
             
Table 1. Immunity - Enclosure port        
  Environmental Test Units Basic Remarks Perf.
  phenomena Specification   EN standard   criteria
1.1 Power-frequency 50 Hz 61000-4-8 See notes 1 and 2 A
  magnetic field 3 A/m      
1.2 Radio-frequency 80-1000 MHz 61000-4-3 The test level specified A
  electromagnetic field 3 V/m   is in the rms value of  
  Amplitude modulated 80 %AM (1kHz)   the unmodulated  
          carrier  
1.3 Radio-frequency 900+/-5 MHz V 50204 The test level specified A
  electromagnetic field 3 V/m   is prior to keying.  
  Keyed carrier 50 Duty cycle %   The test shall be  
    200 Rep.   carried out at one  
      frequency Hz   frequency within the  
          indicated range  
1.4 Electrostatic +/-4 Contact kV (charge 61000-4-2 See basic standard B
  discharge discharge voltage)   for applicability of  
    +/-8 Air kV (charge   contact and/or air  
    discharge voltage)   discharge test B
NOTE 1. Applicable only to apparatus containing devices susceptible to magnetic fields, such as Hall
  elements, electrodynamic microphones, magnetic field sensors, etc.  
NOTE 2. For CRTs the acceptable jitter depends upon the character size and is computed for a test
   level of 1A/m as follows:        
  Jitter (mm) = [3 x character size (mm) + 1]/40      
  As jitter is linearly proportional to the magnetic field strength tests can be carried out at other
  test levels extrapolating the maximum jitter level appropriately.    
             
             
Table 2. Immunity - Ports for signal lines and control lines    
  Environmental Test Units Basic Remarks Perf.
  phenomena Specification   EN standard   criteria
2.1 Radio-frequency 0.15 - 80 MHz 61000-4-6 See notes 1 and 2. A
  common mode 3 V   The test level  
    80 % AM (1kHz)   specified is the rms  
          value of the  
          unmodulated carrier  
2.2 Fast transients +/-0.5 kV (charge 61000-4-4 See note 2. B
      voltage)      
    5/50 Tr/Th ns   Capacitive clamp  
    Jan-00 Rep.   used  
      frequency Hz      
NOTE 1. The test level can also be defined as the equivalent current into a 150 Ohm load.  
NOTE 2. Applicable only to ports interfacing with cables whose total length according to the  
  manufacturer's functional specification may exceed 3m.    
             
             
 
Table 3. Immunity - DC input and DC output  power ports    
  Environmental Test Units Basic Remarks Perf.
  phenomena Specification   EN standard   criteria
3.1 Radio-frequency 0.15 - 80 MHz 61000-4-6 See notes 1 and 2. A
  common mode 3 V   The test level  
    80 % AM (1kHz)   specified is the rms  
          value of the  
          unmodulated carrier  
3.2 Fast transients +/-0.5 kV (charge 61000-4-4 See note 3. B
      voltage)      
    5/50 Tr/Th ns      
    5 Rep.      
      frequency Hz      
3.3 Surges 1.2/50 (8/20) Tr/Th us 61000-4-5 See note 3. B
  line to ground +/-0.5 kV (charge      
      voltage)      
  line to line +/-0.5 kV (charge      
  line to line   voltage)      
NOTE 1. The test level can also be defined as the equivalent current into a 150 Ohm load.  
NOTE 2. Applicable only to ports interfacing with cables whose total length according to the  
  manufacturer's functional specification may exceed 3m.    
NOTE 3. Not applicable to input ports intended for connection to a battery or a rechargeable battery
  which must be removed or disconnected from the apparatus for recharging. Apparatus with a
  DC power input port intended for use with an AC-DC power adapter shall be tested on the AC
  power input on the AC-DC power adapter specified by the manufacturer or, where none is so
  specified, using a typical AC-DC power adapter. The test is applicable to DC power input ports
  intended to be connected permanently to cables longer than 10m.  
             
             
Table 4. Immunity - Input and output AC power ports      
  Environmental Test Units Basic Remarks Perf.
  phenomena Specification   EN standard   criteria
4.1 Radio-frequency 0.15 - 80 MHz 61000-4-6 The test level specified A
  common mode 3 V   is the rms value of the  
    80 % AM (1kHz)   unmodulated carrier  
          See note 1.  
4.2 Fast transients +/- 1 kV (charge 61000-4-4   B
      voltage)      
    5/50 Tr/Th ns      
    5 Rep.      
      frequency kHz      
4.3 Surges 1.2/50 (8/20) Tr/Th us 61000-4-5 See note 2. B
  line to ground +/- 2 kV (charge      
      voltage)      
  line to line +/- 1 kV (charge      
      voltage)      
4.4 Voltage dips 30 % reduction 61000-4-11 Voltage shift at zero B
    10 ms   crossing  
    60 % reduction   See note 2. C
    100 ms      
4.5 Voltage interruptions > 95% % reduction 61000-4-11 Voltage shift at zero C
    5000 ms   crossing  
          See note 2.  
NOTE 1. The test level can also be defined as the equivalent current into a 150 Ohm load.  
NOTE 2. Applicable only to input ports.        
             
             
Table 5. Immunity - Functional earth ports      
  Environmental Test Units Basic Remarks Perf.
  phenomena Specification   EN standard   criteria
5.1 Radio-frequency 0.15 - 80 MHz 61000-4-6 See notes 1. A
  common mode 3 V   The test level  
    80 % AM (1kHz)   specified is the rms  
          value of the  
          unmodulated carrier  
5.2 Fast transients +/-0.5 kV (charge 61000-4-4 See note 2. B
      voltage)      
    5/50 Tr/Th ns   Capacitive clamp  
    5 Rep.   used  
      frequency kHz      
NOTE 1. The test level can also be defined as the equivalent current into a 150 Ohm load.  
NOTE 2. Applicable only to ports interfacing with cables whose total length according to the  
  manufacturer's functional specification may exceed 3m.    
             
             
CE Test duration:   1.5 day typical    
CE Test cost:   1,500US$ typical    
CE Test Report Cost:   600US$ typical (including Emissions)  
CE 2001 Test cost:   2,500US$ typical    
CE 2001 Test Report Cost:   800US$ typical (including Emissions)  
             
             
This is a compilation of information from several standards and should be used only as a quick  
reference. The reader of this article should acquire the actual standards with all the latest  
amendments. Only the actual standards should be used for design and test purposes.  
             